Views: 0 Author: Site Editor Publish Time: 2026-11-27 Origin: Site
Step 1: Fiber optic stripping (most prone to internal damage and hidden breakage)
Tool: fiber stripper
Standard operation
First, peel off the outer sheath, then the buffer layer, and finally the coating layer. Peel in layers. Hard peeling at one time is strictly prohibited
Reserved stripping length: 3-4cm. If it is too long, it is prone to folding; if it is too short, it is difficult to cut and align
The peeler should press gently and pull smoothly. Do not pinch or rotate.
Fatal error-prone points
Residual coating layer and uneven stripping force can cause micro-cracks that are invisible to the naked eye. If the welding is normal at the moment, the core will break directly due to vibration and temperature changes in the later stage, and the attenuation will soar.
Step 2: End face cleaning (the root cause of 90% of the major wear and tear)
Tools: 99.7% anhydrous alcohol + dust-free non-woven fabric
As long as the end face of the optical fiber is stained with even a little dust or grease, the splicing will definitely fail.
Standard operation
Dip a small amount of alcohol in the non-woven fabric and wipe in one direction. Do not rub back and forth repeatedly
After visual inspection, the end face should be transparent, free of white spots, dust and fingerprints
Taboos
Do not dry wipe, do not touch the fiber core with hands, and do not reuse with dirty cloth.
Step 3: Fiber optic Cutting (The core key determining the quality of splicing)
Tool: High-precision optical fiber cutting knife
Whether the welding is good or not depends entirely on whether the cutting is smooth or not.
Machines can correct offsets, but they cannot correct bad cuts.
Standard Operating points
Before cutting, make sure the knife face is clean, free of debris and residual glue
The optical fiber should be laid flat and closely attached to the card slot. It must not be lifted or suspended
The cutting knife moves smoothly and accurately in one go, without any jamming or secondary re-cutting
Cutting Angle requirement: Inclination Angle ≤ 0.5°, the smaller the value, the better
Mandatory checks
After cutting, you must check the end face: it should be flat, free of notches, burrs and chipped edges. If there is even the slightest defect, cut it again directly. Don't rely on luck.
Step 4: Place the welding machine in and calibrate it in position
Common mistakes: misalignment, insufficient pressure, end face too far forward or backward
Standard operation
The two ends of the optical fibers are respectively clamped in the slots, with the fiber cores centered and not shifted
The end face distance is moderate, without touching, adhering or leaving excessive gaps
Cover the wind shield properly to prevent wind, dust and vibration from interfering with the alignment
There is wind and a lot of dust outside the construction site. If the windproof cover is not used for welding, nine out of ten joints will suffer from high wear and tear.
Step 5: Discharge Welding (Machine automatic + Manual judgment)
Nowadays, welding machines are basically fully automatic: automatic alignment, automatic calibration, and automatic discharge.
But the staff must keep an eye on these items:
The alignment process has no deviation and no left or right misalignment
The discharge brightness is uniform and there are no abnormal sparks
The final loss value of the screen meets the standard: single-mode < 0.05dB, multi-mode < 0.03dB
Once the value exceeds the standard, redo it directly. Don't settle for less!
Step 6: Heat Shrink Tube Protection (Key to preventing breakage and cracking)
Many new users experience cracking, bubbling, inability to shrink tightly, and core breakage due to water ingress in the later stage after heat shrinkage.
Standard operation
The heat shrink tube must be inserted into the optical fiber in advance before the splicing process begins (beginners often make mistakes).
After the welding is completed, place the joint in the heating tank with it centered, neither deviating to the left nor to the right
After heating is completed, let it cool naturally. Do not pinch, bend or forcibly pull by hand
Qualified standard for heat shrinkage:
The pipe wall is tight, free of hollows, bubbles and cracks. Both ends are completely wrapped with sheaths, ensuring a tight seal.